Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 32(1): 267-274, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29074128

RESUMO

OBJECTIVE: To compare the incidence of fiberoptic bronchoscope (FOB) use (1) during verification of initial placement and (2) for reconfirmation of correct placement following repositioning, when either a double-lumen tube (DLT) or video double-lumen tube (VDLT) was used for lung isolation during thoracic surgery. DESIGN: A randomized controlled study. SETTING: Single-center university teaching hospital. PARTICIPANTS: The study comprised 80 patients who were 18 years or older requiring lung isolation for surgery. INTERVENTIONS: After institutional review board approval, patients were randomized prior to surgery to either DLT or VDLT usage. Attending anesthesiologists placed the Mallinckrodt DLT or Vivasight (ET View Ltd, Misgav, Israel) VDLT with conventional laryngoscopy or video laryngoscopy then verified correct tube position through the view provided with either VDLT external monitor or FOB. MEASUREMENTS AND MAIN RESULTS: Data collected included: sex, body mass index, successful intubation and endobronchial placement, intubation time, confirmation time of tube position, FOB use, quality of view, dislodgement of tube, and ability to forewarn dislodgement of endobronchial cuff and complications. FOB use for verification of final position of the tube (VDLT 13.2% [5/38] v DLT 100% [42/42], p < 0.0001), need for FOB to correct the dislodgement (VDLT 7.7% [1/13] v DLT 100% [14/14], p < 0.0001), dislodgement during positioning (VDLT 61.5% [8/13] v DLT 64.3% [9/14], p = ns), dislodgement during surgery (VDLT 38.5% [5/13] v DLT 21.4% [3/14], p = ns), and ability to forewarn dislodgement of endobronchial cuff (VDLT 18.4% [7/38] v DLT 4.8% [2/42], p = 0.078). CONCLUSION: This study demonstrated a reduction of 86.8% in FOB use, which was a similar reduction found in other published studies.


Assuntos
Broncoscopia/instrumentação , Desenho de Equipamento/instrumentação , Tecnologia de Fibra Óptica/instrumentação , Intubação Intratraqueal/instrumentação , Cirurgia Torácica Vídeoassistida/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Broncoscopia/métodos , Desenho de Equipamento/métodos , Feminino , Tecnologia de Fibra Óptica/métodos , Humanos , Intubação Intratraqueal/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia Torácica Vídeoassistida/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...